Get Quote
Phone Number


UV UltraVoice Electronic Siren Controller
     
Power    
Input Voltage   120/240±10%, 50/60Hz VAC single–phase
Input Current   5A Maximum
Operating Voltage   24VDC
Standby Current:    
UV
  100mA DC
UVT
  600mA DC
Standby Time   > 7 Days
Continuous Signalling Time   30 Minutes
     
Control Module    
Signal Duration (auto reset)   3 Minutes
Microphone Input Impedance   10k ohms
Audio Distortion   1% THD Maximum
Maximum Load   600 ohms
Contact Closure   (Min) 500 ms<1.0k ohms
     
Amplifier Module    
Frequency Response (300 to 3 kHz)   ±3dB (ref. 1kHz)
Output Voltage (Tone and PA)   (to speaker drivers) 70Vrms
Input Impedance (per amplifier)   100k ohms
     
General    
Operating Temperature*   -22°F to 149°F (-30°C to 65°C)
Enclosures:    
Control Cabinet
  Type 4 or 4X
Battery Cabinet
  Type 4 (vented)
*The siren can operate throughout this temperature range provided the       battery temperature is maintained at 0°F/-18°C or higher.



Battery Requirements
  • Customer must provide necessary batteries
  • Delco Voyager M24MF batteries are required – Call for assistance with specific system requirements


Tone A/B Tone Frequency Range Sweep Rate (Seconds)
Wail

400/480–850/1020

13
Pulsed Wail

400/480–850/1020

1.5/13
Alternate Wail

400/480–850/1020

1.5/13
Steady

850/1020

N/A
Pulsed Steady

850/1020

1.5
Alternate Steady

850/1020

1.5
  Description
  Parts
  Agency
  Diagrams
  Specs
  Ordering Info










Credit Cards