371DST Commander Double Strobe Hazardous Location Warning Light
Voltage
12-24VDC
120VAC 50/60Hz
240VAC 50/60Hz
Mount
Surface
1" Pipe
Operating Current
3.00-1.90 Amps from 12-24VDC
0.60 Amps at 120VAC
0.30 Amps at 240VAC
Dome Colors
Amber
Blue
Clear
Green
Red
Operating Temperature Minimum
-31 F
Operating Temperature Maximum
104 F
Light Source/Lamp Style
Strobe Tube
Lamp Life*
10,000 Hours
Flash Rate/Minute
80 Double Flashes
Candle Power Peak**
750,000
Effective Candle Power***
1,000
Enclosure Rating
Type 4X
Ingress Protection (IP)
IP66
Height
11.38 IN
Width
9.13 IN
*Optimal hours under ideal conditions
**Peak candlepower is the maximum light intensity generated by a flashing light during its light pulse.
***ECP (Effective Candlepower) is the intensity that would appear to an observer if the light were burning steadily.
Federal Signal Distributed by Gross Automation / Brookfield, WI / (877) 268-3700
Description
Parts
Agency
Diagrams
Specs
Ordering Info